Ideal indoor humidity in winter

Keep indoor humidity between 30% and 50%, and cap it lower as it gets colder outside: below 40% when it's 20 to 40°F, below 30% at 0 to 10°F, and below 15% at -20°F or colder. The colder the weather, the less moisture your windows and walls can take before water condenses on them.

Maximum indoor humidity by outdoor temperature

Outdoor temperature Keep indoor humidity
20 to 40°F Below 40%
10 to 20°F Below 35%
0 to 10°F Below 30%
-10 to 0°F Below 25%
-20 to -10°F Below 20%
-20°F or colder Below 15%

Relative humidity. Limits from the Center for Energy and Environment, a Minneapolis nonprofit, 2026. Above 40°F, EPA's general guidance applies: below 60%, ideally 30% to 50%.

Next: Upkeep and fixesHow often to change a furnace filter

Why the limit drops as it gets colder

The University of Minnesota Extension explains that cold winter conditions call for low relative humidity to prevent condensation. The Center for Energy and Environment's table puts numbers on it: humidity capped at 40% in mild cold, stepping down to 15% at -20°F.

The rule of thumb that goes with the table: if moisture keeps building on windows or walls, turn off the humidifier and lower the setpoint (Center for Energy and Environment).

How to use the table

Match the setting to the weather outside. If it's 5°F, keep the house below 30%. If a cold snap brings -15°F, take it below 20%. When the weather warms back up to the 20s or 30s, you can let it rise again to just under 40%, still inside EPA's 30% to 50% ideal.

The table gives ceilings, not targets. The Center for Energy and Environment's own setting for a humidifier is low, 30% to 40%, and in the coldest weather even that is too high: the cap wins.

Signs the humidity is too high

  • Moisture building up on windows or walls. The Center for Energy and Environment's rule: turn off the humidifier and lower the setpoint.
  • A reading above 50%. The University of Minnesota Extension says relative humidity over 50% may cause moisture problems.
  • A reading near 60%. EPA's mold and moisture guide sets 60% as the ceiling for indoor humidity.

Where the sources differ

Three sources give three different numbers:

Source What it says
EPAKeep indoor humidity below 60%, ideally between 30% and 50%
University of Minnesota Extension25% in winter to 50% in summer; above 50% may cause moisture problems
Center for Energy and EnvironmentCaps below 30% once it's 10°F or colder outside, down to 15% at -20°F

They fit together. EPA's 30% to 50% is the ideal range, and it comes from EPA's guidance on mold and moisture. In very cold weather, the lower caps take over to keep water off your windows, which is why the Minnesota sources go below 30%. The Center for Energy and Environment also notes that people are most comfortable at 40% to 60%, so in a cold snap you trade some comfort for dry windows.

How should you run a humidifier in winter?

The Center for Energy and Environment's advice is to run humidifiers for short periods at low setpoints, 30% to 40%, and to turn the setpoint down as the weather gets colder, following the table above. HomeGuide's furnace replacement guide prices a whole-home humidifier at $400 to $1,200 installed.

A furnace-mounted humidifier can also leak. Carrier lists a leaking humidifier or water connection among the causes of water around a furnace; see furnace leaking water.

Is 25% humidity too low in winter?

Not by the Minnesota sources. The University of Minnesota Extension's winter target is 25%, and the Center for Energy and Environment's limit at -10 to 0°F is below 25%. It is below EPA's ideal range and below the 40% to 60% where people are most comfortable, so in milder weather you can run it higher, up to the cap in the table.

What humidity is too high in winter?

Anything that puts water on your windows or walls. Above that, the University of Minnesota Extension says humidity over 50% may cause moisture problems, and EPA's ceiling is 60%.

What about summer and the basement?

The Center for Energy and Environment says to avoid more than 60% in summer and to set a basement dehumidifier to 55%. To size one, use the dehumidifier size calculator. Clean filters matter year round; see how often to change a furnace filter.

Next: Upkeep and fixesHow often to change a furnace filterBy filter thickness, pets and allergies, with MERV explained.

More on air quality

More on heating and cooling

Sources

  1. Managing indoor humidity levels, all year round, Center for Energy and Environment, 2026-07-09.
  2. A Brief Guide to Mold, Moisture and Your Home, U.S. Environmental Protection Agency, 2026-02-18.
  3. Controlling moisture problems in your home, University of Minnesota Extension.
  4. How Much Does a New Furnace Cost? (2026), HomeGuide, 2025-12-31.
  5. Furnace Leaking Water: Causes, Signs, and Solutions, Carrier, 2026-10-13.