Steps
- Pick the spot: outside, at least 20 feet out. CPSC measures the 20 feet from the house. CDC measures it from any window, door or vent, and Ready.gov from windows, doors and attached garages. Meet all of them: at least 20 feet from the house and away from every opening. Not on a porch or in a carport (CPSC). Point the exhaust away from the home, and close the windows and seal the vents near the generator.
- Keep it dry. Run it on a dry surface under an open, canopy-like structure, and don't touch it with wet hands (Red Cross). In rain or snow, follow the manufacturer's instructions; CPSC says these may call for an NFPA-rated noncombustible generator tent, or tell you to wait until the weather passes.
- Put CO alarms inside. CPSC says to use battery-operated or battery-backup carbon monoxide alarms on each level and outside separate sleeping areas, interconnected if you can, and to test them monthly. See where to put carbon monoxide detectors.
- Start the generator, then plug in. Generac says to start it before you connect anything.
- Use the right cords. Plug appliances straight into the generator, or use a heavy-duty, outdoor-rated extension cord rated, in watts or amps, at least equal to the total of everything plugged into it (Red Cross). Check that the cord has no cuts and the plug has all three prongs. Generac says to match the cord's amp rating to the generator outlet and to choose a cord long enough to keep the generator at least 20 feet from the house; CDC says more than 20 feet long. Your generator's manual says which cord suits each outlet.
- Know your load. The cord has to be rated for the total of what you plug in. To check the generator itself, the generator size calculator adds up the running and starting watts of the things you plan to power.
- Refuel only when it is off and cool. Turn the generator off and let it cool down first: gasoline spilled on hot engine parts could ignite (Red Cross). OSHA and Ready.gov say the same.
- Store fuel away from the house. Keep gasoline in an approved safety can (OSHA adds properly marked and vented), outside living areas in a locked shed or other protected area, and not near a fuel-burning appliance such as a gas water heater in a garage. Local laws may limit how much you can store (Red Cross).
Never in the garage, even with the door open
CPSC's rule is in capitals: "NEVER operate a portable generator inside a home, garage, basement, crawlspace, shed or other enclosed spaces. Opening doors or windows will not provide enough ventilation to prevent the buildup of lethal levels of CO." CDC's only exception is equipment that is professionally installed and vented. The Red Cross adds that fans won't prevent the buildup either.
CDC lists the common symptoms of carbon monoxide poisoning as headache, dizziness, weakness, nausea, vomiting, chest pain and confusion. People who are asleep or have been drinking can die before they have any symptoms, which is why the alarm matters. If yours goes off, see what each beep pattern means, then get out first.
Why you can't plug a generator into a wall outlet
Plugging a generator into a wall outlet to power the house wiring is called backfeeding. The Red Cross says it puts utility workers, your neighbors and your household at risk of electrocution. OSHA explains why: without a properly installed transfer switch, a generator can energize wiring "for great distances," putting utility workers and others in the area at risk. To run house circuits, have an electrician install a transfer switch.
How many people die from generator carbon monoxide?
CPSC estimates that in 2022, 274 people died of carbon monoxide poisoning linked to consumer products other than fires, and 93 of those deaths involved generators. From 2020 to 2022, generators alone averaged an estimated 98 deaths a year, out of 238 a year from all consumer products. Over 2012 to 2022, generators were linked to more deaths (892) than heating systems (622), and about 74% of the 2020 to 2022 deaths happened at home.
A separate CPSC count of reported cases found 749 deaths in 583 incidents involving generators from 2012 to 2022, 742 of them with portable generators, with 2021 and 2022 still incomplete. Among power-outage incidents with a known cause, ice or snow storms accounted for 35% of the fatal incidents and 31% of the deaths. The two reports use different methods, a national estimate and a count of known cases, so both are right.
Should you buy a generator with CO shutoff?
CPSC says to look for portable generators with a carbon monoxide shut-off safety feature. Two voluntary standards added carbon monoxide rules in 2018: UL 2201 and ANSI/PGMA G300. Both require the generator to shut off when the carbon monoxide around it passes a set level, and UL 2201 also caps its weighted emission rate at 150 grams an hour. The 2023 update to G300 lowers the shut-off levels for generators made after January 1, 2025 that claim to meet it.
Both standards are voluntary. CPSC proposed a mandatory rule in April 2023; the fall 2025 federal regulatory agenda lists it at the final rule stage, and we found no final rule as of November 2026. CPSC staff found conformance to the voluntary standards to be low in a February 2022 briefing, so check that the model you buy lists one of them.
More on generators
Watts to amps calculator
Amps from watts and volts, and back, for 120 V and 240 V circuits.
Generator size calculator
Running and starting watts for what you need to power.
More on electrical
Sources
- Winter Storm May Knock Out Power; CPSC Warns of Deadly Carbon Monoxide and Fire Risks, U.S. Consumer Product Safety Commission, 2026-02-19.
- Non-Fire Carbon Monoxide Deaths Associated with the Use of Consumer Products, 2022 Annual Estimates, CPSC, 2026-05-27.
- Fatal Incidents Associated with Non-Fire Carbon Monoxide Poisoning from Engine-Driven Generators and Other Engine-Driven Tools, 2012-2022, CPSC, 2024-02-21. Data as of 2023-04-17.
- Safety Standard for Portable Generators, RIN 3041-AC36 (Unified Agenda entry), Office of Information and Regulatory Affairs / CPSC, Fall 2025.
- Safety Standard for Portable Generators (supplemental notice of proposed rulemaking), 88 FR 24346, Federal Register / CPSC, 2023-04-20.
- PGMA Updates Standards to Reduce Exposure to Carbon Monoxide, Occupational Health & Safety (OH&S), 2024-03-26.
- Safe Generator Use, American Red Cross (with technical advice from CDC, NFPA, CPSC).
- Power Outages, Ready.gov (FEMA), 2026-06-04.
- What to Do to Protect Yourself During a Power Outage, CDC, National Center for Environmental Health, 2026-08-26.
- Using Portable Generators Safely (Fact Sheet OSHA 3286), Occupational Safety and Health Administration, 2005.
- Power Cords vs. Extension Cords: How to select the right power cord and extension cord for your portable generator, Generac (support knowledge base), 2025-06-10.