Defrost: a few minutes of cool air is normal
In winter, frost builds on the outdoor coil, and the heat pump melts it by reversing for a few minutes. Lennox says most systems check for frost every 30 to 90 minutes in heating mode. Trane says defrost is more likely when it's in the 20s and 30s°F, and can start in the low 40s.
What it looks and sounds like, per Lennox and Trane:
- Steam rising from the outdoor unit.
- A whoosh or swoosh as the refrigerant reverses direction.
- The outdoor fan stops.
- Cool air at the vents if there's no backup heat. Many heat pumps switch on backup heat strips during defrost, and the thermostat may show AUX while they run.
How long defrost lasts, by brand
| Brand | Defrost length | Detail |
|---|---|---|
| Trane | Usually 3 to 5 minutes | Demand defrost ends as soon as the ice is cleared |
| Carrier | About 5 to 10 minutes | |
| Lennox | Usually 5 to 15 minutes | Checks for frost every 30 to 90 minutes |
The three makers give different figures, each in its own consumer guide. Your model's manual is the one to go by. If ice stays on the coil after defrost, see heat pump iced over.
Heat pump air feels cooler than furnace air
Carrier puts heat pump supply air at roughly 85 to 100°F, against 120 to 140°F from a gas furnace, so heat pump air feels cooler even when the system is working as it should. If you're deciding between the two, see heat pump vs furnace.
Check the thermostat
Lennox lists the thermostat on Cool or the fan on On among the causes. Set the mode to Heat and the fan to Auto, then raise the setpoint by at least 5 degrees (Lennox) to make the system call for heat.
Check the filter
A clogged filter is on Lennox's list too. Hold it up to a light and replace it if you can't see through it. Carrier says to clean or replace a heat pump's filter every 60 to 90 days; see how often to change a furnace filter for the full schedule.
Clear the outdoor unit
Leaves, snow or ice packed around the outdoor unit block it (Lennox). Turn off the outdoor disconnect first, then clear debris and snow and keep 2 feet (24 inches) clear on all sides, as Lennox and Carrier advise. Reset a tripped breaker once; if it trips again, call a technician.
Backup heat, emergency heat and the balance point
Older heat pumps may struggle below 25 to 30°F, Carrier says, while cold-climate models can work well below zero. When the heat pump can't keep up, auxiliary heat fills in. Lennox explains it with two set temperatures: above the high balance point only the heat pump runs, below the low balance point only the auxiliary heat runs, and between them both may run.
A Bonneville Power Administration program spec sets these limits: a balance point no higher than 30°F, strip heat locked out at 35°F or lower, and the compressor allowed to run at every outdoor temperature. Some makers call the strip-heat lockout the "high balance point" and the compressor lockout the "low balance point."
Emergency heat runs the electric resistance strips. Carrier says to use it sparingly, because it "can significantly raise bills." If your heat pump runs short of heat on most cold days, check its size against your winter lows with the furnace and heat pump size calculator.
Low refrigerant or a stuck reversing valve
Low refrigerant reduces how much heat the system can move. A stuck reversing valve can blow cold air in heat mode while cooling still works. Both need a pro (Lennox, Carrier). This Old House puts the average air-source heat pump repair at about $798.
When to call a pro
Carrier's list:
- Ice stays on the outdoor unit after defrost.
- Defrost happens unusually often.
- Breakers keep tripping.
- Heating fails while cooling works.
More on heat pumps
Heat pump vs furnace
Running cost, comfort in the cold, lifespan and install cost.
Heat pump iced over
Normal frost or a frozen block, and what you can safely do.
How often to change a furnace filter
By filter thickness, pets and allergies, with MERV explained.
Heat pumps
Installing a heat pump: types, costs, sizing, upkeep and fixes, in order.
Heat pump installation cost
Ducted and ductless, by size and efficiency, priced for your state.
AC size calculator
BTUs and tons of cooling for your square footage and climate.
Furnace and heat pump size calculator
Heating BTUs for your home and winter lows, for a furnace or heat pump.
All of heat pumps · More on heating and cooling
Sources
- Understanding the Heat Pump Defrost Cycle, Lennox, 2025-11-10.
- What Is a Heat Pump Defrost Cycle?, Trane, 2026-02-19.
- Heat pump blowing cold air, Lennox, 2026-02-17.
- Heat Pump Not Heating? Here's How to Troubleshoot, Carrier, 2026-09-15.
- Heat Pump Troubleshooting Guide: Is Your Heat Pump Not Working?, Carrier, 2026-09-15.
- What are low and high balance points?, Lennox, 2026-03-19.
- PTCS Lockouts and Balance Points: Reference Guide, Bonneville Power Administration. PDF file dated 2021-09-13.
- How Much Does a Heat Pump Cost? (2026 Pricing), This Old House, 2026-10-14.